A useful field-testing routine begins before the first process sample. The aim is to know which instrument and method produced a result, whether the planned checks passed and what happened if they did not. A checklist should support that record without turning a simple measurement into unnecessary paperwork.

The USGS National Field Manual is a useful reference for planning documented water-quality measurements. Your own procedure must still match the instrument, sample and purpose of the work.

Prepare the kit around the planned measurements

Start with the parameter list and expected sample conditions. Confirm that the instrument, sensors, cells and reagents support those methods. Charge batteries, check cables and seals, and take the current operating instructions. A spare battery is useful only if it is the correct type and ready for service.

Check that standards and reagents are within their stated use period and have been stored as directed. Record their identifiers where required by the site's quality system. Separate material that is damaged, contaminated or of uncertain history instead of treating its presence in the case as proof that it is usable.

Distinguish calibration from verification

Calibration establishes or adjusts the relationship used to report a result. Verification checks performance against suitable reference material and acceptance criteria. Zeroing is another specific operation and should not be recorded as though it completes every quality check.

Use the manufacturer's procedure and the site's approved method to decide what is required before, during and after a session. There is no single universal interval or tolerance for every portable analyser. Define what happens when a check fails before taking the kit into the field.

Identify the measurement before collecting it

Give the sample point a stable name. Record the collection time and, where different, the measurement time. Include the instrument or probe identifier, programme, unit and operator. Note relevant conditions such as a recently cleaned sample point or a process change.

That information makes a result useful after the operator has left the site. It also prevents a common problem: a spreadsheet that contains convincing numbers but no reliable way to tell which tank, method or instrument they belong to.

Respond consistently to a failed check

Keep the failed result and the action taken. Follow the approved troubleshooting sequence and record any cleaning, replacement or recalibration. If the procedure requires reviewing earlier results, identify the affected period rather than quietly overwriting the readings.

When the reason remains uncertain, report that uncertainty. A second instrument or laboratory comparison can help only if the samples, times and methods are suitable for comparison. Repeating measurements until one looks plausible does not establish a defensible result.

Close the session properly

Complete any required end-of-session checks, export or save the data, and clean and store the equipment as instructed. Flag consumables that need replacement before the next visit. A short handover should leave the next operator able to distinguish a ready kit from one awaiting investigation.

Explore our portable water-quality analysers with PMA, or read the PMA News introduction to the portable range for application context.

Frequently asked questions

Is a factory calibration enough for all future field use?

It does not remove the need for the checks, maintenance and verification required by the instrument's instructions and the site's method.

How often should I check a portable analyser?

Set the frequency through the relevant procedure, considering the instrument, application and quality requirements. Do not apply an arbitrary interval across different technologies.

Should a failed reading be deleted?

Retain it with an appropriate flag and explanation. Follow the site's record-control process so the investigation remains traceable.

Can PMA help define the equipment list?

Contact PMA with your parameters, sample types, expected ranges and existing methods so the discussion starts with the measurement task.