Description
Key features
High Precision: The MD 100 delivers accurate and reliable measurements across a wide range of water quality parameters, ensuring high precision in your results.
Portable Design: Compact and lightweight, the MD 100 is perfect for on-site testing and easy transportation, making it an ideal solution for fieldwork.
User-Friendly Operation: The intuitive interface and clear display allow for easy operation, even for users with minimal technical experience.
Versatile Measurement Capabilities: The MD 100 can measure multiple parameters, including chlorine (free and total), pH, and more, providing comprehensive water quality analysis in one device.
Durable Construction: Built to withstand challenging environments, the MD 100 is rugged and waterproof, ensuring long-lasting performance in various conditions.
Why Choose the MD 100?
The MD 100 stands out as a reliable, high-performance photometer for water quality testing. Its advanced features, robust construction, and user-friendly design make it the preferred choice for professionals seeking accurate and efficient water quality analysis.
Applications include
Drinking Water Analysis
Pool and Spa Water Testing
Wastewater Treatment Monitoring
Industrial Process Water Testing
Environmental Water Quality Assessment
Specifications
- Measuring Range: Wide range to cover all necessary water quality parameters.
- Display: Clear, easy-to-read display for accurate result interpretation.
- Data Storage: Capable of storing multiple data sets for efficient data management.
- Power Supply: Long-lasting battery life with options for rechargeable batteries, ensuring continuous operation.
- Portability: Lightweight and compact design for easy field use.
What water quality parameters can the MD 100 measure, and how does it maintain accuracy across these different measurements?
The MD 100 can measure a variety of water quality parameters, including free and total chlorine, pH, and more. It maintains accuracy through advanced photometric technology, which includes automatic wavelength selection and calibration to ensure precise and reliable measurements across all parameters.
How do you ensure the MD 100 remains accurate in environments with varying temperatures and humidity levels?
The MD 100 is designed to perform reliably in a wide range of environmental conditions. It features automatic temperature compensation to maintain accuracy despite temperature fluctuations. For optimal performance, it is recommended to store the device in a controlled environment and perform regular calibration checks.
Can the MD 100 be used for regulatory compliance testing, and what standards does it adhere to?
Yes, the MD 100 can be used for regulatory compliance testing. It adheres to several international standards, including ISO and EPA guidelines, ensuring that your measurements meet the required regulatory standards. The device’s calibration and testing methods are designed to provide results that are compliant with these regulations.
What is the procedure for calibrating the MD 100, and how often should calibration be performed?
Calibration of the MD 100 involves using standard solutions to adjust the device’s readings for accuracy. This can be done through a straightforward process outlined in the user manual. Calibration frequency depends on usage intensity; for routine use, monthly calibration is recommended, while for critical applications, weekly calibration or before each major testing session is advisable.
How does the MD 100 handle samples with high turbidity, and is there a specific protocol for such conditions?
The MD 100 is equipped to handle samples with varying turbidity levels. For high turbidity samples, it is recommended to filter the sample or allow it to settle before testing to ensure accurate measurements. The device’s photometric system is designed to minimize the interference caused by turbidity, but proper sample preparation is key to maintaining accuracy.
What are the best practices for maintaining the optical components of the MD 100 to ensure long-term accuracy?
To maintain the accuracy and longevity of the MD 100’s optical components, it is essential to keep the sample chamber and optical path clean. Regularly inspect and clean these parts using a soft, lint-free cloth and appropriate cleaning solutions. Avoid using abrasive materials or harsh chemicals. Additionally, store the device in its protective case when not in use to prevent dust and debris accumulation.
Meet Your AI Assistant: Here to Help!
Meet our new AI Assistant, designed to answer all your questions about our portable water quality analysers. Whether you need help with product specifications or application requirements, our AI Assistant is available 24/7 to provide accurate and timely information. Explore the benefits of our advanced testing devices quickly and confidently; knowing expert help is just a click away.
Get in touch with us
Reach out to us through our online contact form for your portable analyser questions, and you’ll be automatically entered into our prize draw for a chance to win an Apple HomePod!